Manual 1.0.130Download PDF

Chapter 15New analysis views

In the investigation layout, the panel below the graph shows four views to the left of the per-analysis tabs of Chapter 9. Each view gathers the results of several analyses, or all series, into one picture so that you can see where to look first.

View What it shows Calculation
Incidents "Incidents": findings of the analyses grouped by time, and the series that moved together in each incident Built from the results of the full diagnosis and other analyses
Series map Which series moved, and when (all series in one picture) Build the map
Time-frequency When a frequency component that is not usual appeared in the target series Calculate
Sensor health Signs of sensor trouble (broken wire, poor contact, missing values, and so on) Run check

All four views are calculated with the run button inside the view (there is no card in the sidebar). The results are not saved in the file (.lgd). They are cleared when you load data again, so run the view again.

The examples in this chapter use the sample data sample_endurance_run_en.csv (Incidents and Series map), made-up data with sensor faults (Sensor health) and made-up data in which a frequency component is added partway through (Time-frequency).

15.1Where the results are placed (below, right, full screen)

Use the three buttons at the right of the panel header to choose where the results are placed.

Button Placement
Bottom Below the graph (the initial setting). Drag the border to change the height
Right To the right of the graph, from top to bottom. Drag the border to change the width. Double-click the border to fold the panel into a thin strip
Full screen Spreads the results over the whole graph area. Click Exit full screen or press Esc to return to the previous placement

With Right, you can see the results in a large area without making the graph shorter. The placement and the width are part of the settings. Full screen is a temporary display and is not part of the settings.

With Full screen, Sensor health, the incident details of Incidents and Time-frequency change to a layout with larger figures. Below or on the right, they keep the compact layout.

15.2What happens when you click a result

Clicking a result (a table row, a card, a cell in a figure) works the same way in the views of this chapter and in the analysis tabs of Chapter 9.

Action Result
Click Shows that place on the graph. The related series are shown for now if they are not displayed, the position is highlighted, and the graph moves there if it is outside the view
Click the same item again Undoes it (hides the series shown for now and removes the highlight)
Click another item Replaces it (the series shown for now by the previous click are hidden)
Ctrl + click Adds it, keeping the previous ones. Ctrl + click a series that is shown for now to remove only that series
Double-click Zooms in to that position. With Full screen, the results return to their placement first, and then the graph zooms in

A "Focus" bar appears above the graph. It shows what you are looking at, which result it came from and how many series are shown for now.

  • Click Keep on chart (Keep all when there are several) to keep the series shown for now on the graph. Series you check yourself in the series list also stay
  • Click ✕ on the bar or press Esc to undo
  • Clicking an empty part of the graph removes only the highlight (the series shown for now stay)
  • Hide series shown for now in the sidebar also hides the series shown for now

15.3Incidents

Incidents groups the findings of Change point, Event analysis, Outlier, Freq. anomaly and Corr. break that overlap or are close in time, and lists them as "incidents". The incidents are about the target series of the analysis.

If no analysis has been run yet, the Run full diagnosis button appears. When the full diagnosis finds incidents, the Incidents tab opens after the diagnosis.

Incident list (full screen, Vibration RMS of the sample, after the full diagnosis)
Figure 15-1Incident list (full screen, Vibration RMS of the sample, after the full diagnosis)
  1. 1One-line summary: the largest incident and what happened
  2. 2Order: By time or By size (the numbers stay in time order)
  3. 3Incident cards: number, time, type, a small waveform and a sentence. The largest incident has Largest
  4. 4Evidence meter: which analyses found this incident (each analysis that found it has its own color; analyses that did not find it and analyses not run yet can also be told apart)
  5. 5Zoom here and Details

The type of an incident is decided from the strongest evidence and the levels (medians) before, during and after the incident.

Type Meaning
Temporary rise, Temporary drop Goes up (down) and returns to the previous level
Step up, Step down Goes up (down) one step and does not return
Small change The level changes slightly
Broken relation The usual relation with another series weakens (Corr. break)
Frequency change The frequency content changes (Freq. anomaly)
Outliers Outliers only
Sudden moves Sudden movement (Event analysis)

While the Incidents tab is open, numbered flags and light bands for the incidents appear on the graph, and incident marks appear on the overview waveform.

Incident details

Click Details on a card to run the same calculation as Known event investigation in Chapter 9 on the incident's range and find the series that moved with it (the settings and results of the Known event investigation card are not changed).

Incident details (full screen)
Figure 15-2Incident details (full screen)
  1. 1Incident number, time, length and a sentence (which series moved first and which moved at the same time)
  2. 2Previous, Next, Back to list
  3. 3Waveforms in the order they moved: series that moved earlier are higher. ▼ marks the start of the movement and the dotted line connects them. The level change and the correlation are on the right
  4. 4Before, during, after: median and spread of the target series in each window
  5. 5Related series and time difference: series that moved first are on the left, series that moved later on the right
  6. 6Evidence by analysis
  7. 7Show this range on the graph, Show related series on the graph, Export CSV
  • In full screen, switch the order of the waveforms with Order moved and Strongest relation
  • Series shown with Show related series on the graph stay on the graph (they are not shown only for now)
  • For an incident that changes one step (a step or a small change), "during" is extended to after the change, and the two windows before and after are compared

Export an incident to CSV

Click Export CSV to export the incident details to one CSV file.

  • Lines at the top (starting with #): incident number, range, type, target, the before/during/after windows and the X unit
  • Table: for each series, the class (leading, same time, lagging), unit, time lag, level change, correlation and the before/during/after medians
  • Then: X and values of the series drawn in the waveforms (around the incident)

15.4Series map

Series map runs the same calculation as Change point on every series and lays out in one picture which series moved, and when. The time is divided into cells, which are painted in three brightness levels by the strength of the change (brighter means a stronger change).

Series map (full screen, made-up data with sensor faults)
Figure 15-3Series map (full screen, made-up data with sensor faults)
  1. 1Summary: the time when the most series moved together
  2. 2Order: By first move, By size, By name
  3. 3Total of all series: a band with the number of series that moved at each time
  4. 4One row per series: bright cells are where that series moved. Click a cell to show that series for now and highlight that time (double-click to zoom in)
  • The calculation uses the whole data range (the Range setting is not used)
  • The threshold for lighting a cell is twice the threshold of Change point (with the same threshold, series that only fluctuate would light up). The window is the window of the Change point result if there is one, otherwise 1/50 of the whole range
  • If there are Incidents results, a column of incidents is shown; if there are Sensor health results, marks for missing values and suspected sensor trouble are shown
  • With many series, only the top series that moved are shown, and the number of the rest is given

15.5Time-frequency

Time-frequency lays out the target series of the analysis in one picture with time (horizontal) and frequency (vertical). The waveform is above, and the strength of each frequency band is below, on the same time axis.

Time-frequency (full screen)
Figure 15-4Time-frequency (full screen)
  1. 1Switch between STFT and Wavelet, and the color scale of the figure (Weak to Strong)
  2. 2From the top: the waveform, the time-frequency figure and Strength by band. In the figure, brighter means a stronger component, and the dotted line is the Main frequency (dotted). A range where a component that is not usual stands out is framed, with its frequency and how many times the usual level it is. On the right, the spectrum at the cursor is drawn vertically over the Usual (median of all) (the peaks line up with the frequency rows of the figure)
  3. 3Cursor card: time, Main frequency and the difference from usual
  • The window and step use the STFT settings in Chapter 8. For short data, the window is reduced down to 1/16 of the whole range. Wavelet uses the settings of the Wavelet analysis
  • "Usual" is the median of all windows for each frequency. To avoid mistaking the skirt of the main peak for a new component, the comparison uses the largest usual level among nearby frequencies
  • The one-line summary is made from bands that are not present usually and become strong for a while (for example, "Between ... , a 230 Hz component appears in addition to the usual 50 Hz")
  • When a prominent component is at the edge of the calculated frequency range, a note says that it may be outside the range
  • Click the figure to see that time on the graph; double-click to zoom in
  • The calculation uses the whole data range. When you change the target series, the previous result is cleared

15.6Sensor health

Sensor health goes through the raw data of every series without thinning it out and picks up signs of sensor trouble. The judgment is made by fixed rules; no machine learning is used.

Sensor health (full screen, made-up data with sensor faults)
Figure 15-5Sensor health (full screen, made-up data with sensor faults)
  1. 1Summary and count tiles (Suspect, Caution, Normal)
  2. 2Sensitivity and Check again
  3. 3Rows of series to check: name, judgment, type, small waveform and details
  4. 4Enlarged figure of the selected row and Why it was flagged
  5. 5Exclude this span from analysis, Zoom here, Mark as fine
Type Judgment What is picked up
Stuck (possible open circuit) Suspect Jumps to the maximum or minimum value of the series and stays there
Dropouts (possible loose contact) Suspect Briefly (up to 5 points) jumps to the maximum or minimum value and comes back, 3 times or more
Frozen Caution The same value continues from some point (including the same value from start to end)
Missing Caution Missing values continue for 5 points or more, or make up 1% or more of the whole
Noise change Caution The spread of the differences between neighboring points changes to 4 times or more, or 1/4 or less, of usual and stays so
  • The length of "the same value continues" is decided for each series (from how often the series usually repeats the same value, a length that does not happen by chance is found). The required length is given in Why it was flagged
  • Signals with steps (long flat parts in several places) and signals with few kinds of values (such as operating states) are not checked
  • A series that slowly approaches its upper limit and stops (without a jump) is judged Frozen (Caution), not Stuck
  • Sensitivity has three levels: Standard, Catch small ones and Large ones only
  • The reason also says whether other series of the same kind (series with the same unit whose names differ only by a number, such as T1 and T3) moved at the same time. If only one series stays still while the others move, sensor trouble is more likely
Button Result
Zoom here Zooms in to that range
Mark as fine Removes the row from the list. Restore puts it back
Exclude this span from analysis Stops all analyses from using the points in that range (from the next analysis you run). Click again (Include in analysis again) to undo. Excluded ranges are not saved (they are cleared when you load data again)

In full screen, the count tiles, the list of series to check (with a time scale), a large enlarged figure and examples of What it can find are shown. Click Show the list to see the names of the series judged normal.